Description
COMPRESSED AIR DRYER
STAINLESS STEEL REFRIGERATED DRYER
Suitable for Food Industry, Biomedical Industry and High-End Electronics Industry, etc.
- 304 stainless steel plate-fin heat exchanger.
- Remove moisture, impurities and some pollutants from compressed air.
- It can be used with sterilizing filter to remove harmful substances in compressed air. It is suitable for high air quality requirement such as medical treatment.
Correction Factor
Factor A (Inlet temperature correction factor) | |||||||
---|---|---|---|---|---|---|---|
Inlet Temp (˚C) | 50 | 55 | 60 | 65 | 70 | 75 | 80 |
Factor | 1.15 | 1.1 | 1.07 | 1.05 | 1 | 0.97 | 0.93 |
Factor B (Working pressure correction factor) | |||||||
---|---|---|---|---|---|---|---|
Working Pressure (Mpa) | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 0.98 |
Factor | 0.75 | 0.85 | 0.92 | 1 | 1.05 | 1.12 | 1.2 |
Factor C (Ambient temperature correction factor) | |||||
---|---|---|---|---|---|
Ambient Temp (˚C) | 30 | 32 | 35 | 40 | 42 |
Factor | 1.03 | 1 | 0.96 | 0.9 | 0.8 |
Factor D (Dew point correction factor) | ||||
---|---|---|---|---|
Dew Point (˚C) | 0 | 2 | 5 | 7 |
Factor | 0.8 | 0.9 | 1 | 1.1 |
Flow rate calculation = Max flow rate air compressor ÷ (A x B x C x D)
Technical Parameter
Model | Flow Rate | Power Supply | Dimensions | Weight | Connections | |||
---|---|---|---|---|---|---|---|---|
M3/min | Cfm | V/Ph/Hz | L | W | H | Kg | ||
YC-7SS | 0.8 | 28 | 240/1Φ/50Hz | 400 | 320 | 505 | 39 | ¾” |
YC-10SS | 1.5 | 53 | 400 | 320 | 505 | 40 | ¾” | |
YC-15SS | 2.3 | 81 | 580 | 480 | 700 | 45 | 1’’ | |
YC-20SS | 2.9 | 103 | 580 | 480 | 700 | 46 | 1’’ | |
YC-30SS | 4.3 | 152 | 400 | 600 | 1055 | 50 | 1’’ |
Working Pressure | : 7 bar (Max. 16 bar) |
Inlet Air Temperature | : 70˚C |
Ambient Temperature | : 32˚C |
Dew Point | : 5 ~ 10 ˚C |
Refrigerant Type | : R134a or R407c |